CONSTRUCTION INSPECTOR'S CHECKLIST FOR PILING

Precast Concrete Piles is the penetration of all foundation piles below the minimum tip elevation? the interior of all driven metal shell piles for bends or other deformations that would impair the strength of the pile with a Contractor-supplied lamp or mirror? (512 04(c Get Price

5 BORED CAST

5 8 Reinforcement The number of joints in longitudinal steel bars shall be kept to a minimum Joints in reinforcement shall be such that the full strength of each bar is effective across the joint and shall be made so that there is no detrimental displacement of the reinforcement during the construction of the pile 5 9 Placing concrete 5 9 1 Get Price

PILE DRIVING INSPECTION MANUAL

3 3 Concrete Piles Concrete piles in New York are precast and prestressed The piles are cast in a pre-casting plant and then transported to the site This creates a pile made of high quality concrete under controlled casting and curing conditions The process Get Price

Definition of Concrete MPa

The MPa of new concrete is determined using a cylinder-testing process Inspectors bore concrete cylinders after the surface has dried or cured for 28 days The cylinders must be transported carefully to testing labs where they are placed on testing machines Get Price

Bored Pile Foundation Techniques and Benefits

(b) Concrete for Piles Unless otherwise stated concrete used shall comply with Specification on Concrete for Structures and as approved by the Engineer The grade of concrete shall be 35 (characteristic strength of 35 N/mm2 at 28 days) with minimum cement content of 400kg per cubic meter of concrete Get Price

Foundations for Difficult Sites

The main difference from augered piling is that the drilling pieces are hollow so concrete can be pumped directly to the bottom of the hole as the auger is withdrawn Driven piles use a steel casing and are suitable for wet unstable or contaminated ground More economical than the CFA method these piles come in sizes varying from 150mm to 320mm Get Price

Extraction Of Pile Casings Support Of Pile Reinforcement

Extraction Of Pile Casings Support Of Pile Reinforcement Cages Risk to the reinforcement being displaced by sinking into the wet concrete Risk to the integrity of the pile shaft Procedures Step 1 /3 Once the reinforcement cage has been placed into the pile bore Get Price

BORED PILING METHOD STATEMENT

Download Bored Piling method statement for construction projects The scope of this procedure covers the control of installation of Bored Cast-in-Situ Concrete piles executed by a sub-contractor 2 Hany Ismael is the founder and CEO of Planning Engineer Est in Egypt Get Price

Blog

Dewatering for Basement Construction 12 March 2016 Many excavations for basement construction will encounter groundwater This is obviously not ideal – most designers and contractors would prefer a 'dry' job to a 'wet' one If not suitably managed and controlled groundwater can cause problems for excavation and basement construction Get Price

Pile cropping

When the concrete has cured for a minimum of about 7-days cropping work can proceed Cropping is carried out by drilling a hole into the side of the pile at cut off level and using a split tube and wedge (either hydraulically powered on larger piles or hand driven on smaller piles to split the concrete) Get Price

SAMPLE SPECIFICATION for PILE INTEGRITY TESTING

SAMPLE SPECIFICATION for PILE INTEGRITY TESTING by the LOW STRAIN IMPACT METHOD integrity testing shall not be performed until the concrete has cured for a minimum of seven (7) reductions in pile area or pile material strength or stiffness above the pile toe are observed the pile has Get Price

Compressive Strength of Concrete Concrete Cubes

Compressive strength as per American Codes In case of American codes compression strength is defined in terms of cylinder strength fc' Here compressive strength of concrete at 28 days curing is obtained from a standard cylindrical specimen 150mm diameter and 300mm high loaded longitudinally to failure under uniaxial compression loading Get Price

Design and Construction of Auger Cast Piles

strength of grout ( 4 000 to 5 000 psi the hole when constructing piles through soft ground Concrete slump for CFA construction is similar to that of wet-hole drilled shaft construction with target slump values in the 8 in 1 in range Design and Construction of Auger Cast Piles Get Price

Various Lab Test On Concrete

Various Lab Test On Concrete Posted in Material Testing of existing buildings or structures where as in destructive test a sample is made and then destroyed to find out the strength of concrete Compression test is the example of destructive test Nd i want to know abt some intrvw asked Ques and trick nd process for estimation Thanks Get Price

Concrete and reinforced concrete

When the concrete sets and hardens around the bars we get a new composite material reinforced concrete (also called reinforced cement concrete or RCC) that works well in either tension or compression the concrete resists squeezing (provides the compressive strength) while the steel resists bending and stretching (provides the tensile Get Price

Role of Concrete Curing

Curing plays an important role on strength development and durability of concrete Curing takes place immediately after concrete placing and finishing and involves maintenance of desired moisture and temperature conditions both at depth and near the surface for extended periods of time Get Price

Contiguous Pile Wall as a Deep Excavation Supporting System

Contiguous Pile Wall as a Deep Excavation Supporting System Venkata R GODAVARTHI Dineshbabu MALLAVALLI Ramya PEDDI Neelesh KATRAGADDA and Prudhvikrishna MULPURU 147 Figure 2 Soldier pile with wooden lagging walls Sheet pile Wall Figure 3 Sheet pile wall Sheet pile Wall Figure 4 Anchored Sheet pile wall Sheet pile Wall Wales Struts Figure 5 Get Price

The Advantages And Disadvantages Of Pile Foundations

Adequate reinforcement of the precast concrete piles is necessary as this helps to make them bear stresses of being transported to location and when driven into the ground Adequate pre-planning is essential for the proper handling of the pile when driven into the ground The process of driving the piles requires heavy equipment Get Price

TECHNOLOGY Bored Piles

The construction process consists of drilling the pile removing loose material from the borehole placing no more than 3-4 m of piping is immerged in the wet concrete at any one time Once the concrete has reached the pre-established An auger or a bucket can be used to bore cohesionless soil or average compacted clay Get Price

12 State of Practice for the Design of Socketed Piles in Rock

State of Practice For the Design of Socketed Piles in Rock P J N Pelis asc (Eng) MSc (Eng) DIC DSc(Eng) Partner Pells Sullivan Meynink Pty Ltd Australia Development over the past three decades in design methods for axial and lateral loads on rock Summary socketed piles are summarised Get Price

Concrete Vibration Handbook

2 CONCRETE VIBRATION HANDBOOK Cement Pound-for-pound this is the most expensive ingredient in concrete Several types of cement are available to meet different construction criteria Water content—curing In order to begin the hydration process water is needed to act as a catalyst Water content will determine the strength workability and Get Price

BORED PILES (WITHOUT PERMANENT CASING)

bored reinforced concrete piles without permanent casing 2 Methodology of concrete placement and process in place to avoid which specifies minimum strength and other requirements for the concrete classes as nominated in the drawings to achieve the required durability Get Price

SOCKETING OF BORED PILES IN ROCK

Socketing of Bored Piles in Rock 681 Equation 3 can be used to arrive at socketing length of pile to get the capacity of pile equal to its structural strength Another method by using chisel is also in practice to determine the type of rock and socket length In the chisel energy method the main points to be considered are weight = Get Price

Concrete Drainage Pipes

Concrete pipes dating back to Roman times have been discovered in the United Kingdom and users of Marshalls CPM precast concrete pipes have the security of a design life of 120 years that ensures lifetime costs are kept to a minimum All precast concrete pipes manufactured to class 4 (DC4) sulphate resistance in accordance with the Get Price

Concrete vs Shotcrete What's the Difference?

The nuances and differences between concrete and shotcrete are too numerous to cover in a short article Selecting a concrete placement method whether it be conventional concrete wet-mix or dry-mix process shotcrete can be a challenging task since there Get Price

Concrete Footing Solutins to Common Problems

Another option is to excavate out the soft soil and replace it with compacted gravel or low-strength concrete also called lean fill But in many cases widening the footing is the simplest solution If you've got a 16-inch footing increasing that to 32 inches doubles your bearing area making the footing suitable for soil with half the capacity Get Price

Driven Bored Piles

Bored Pile installation Quality control is very important during installation of bored piles Allrigs are equipped with a special computer system to control a pileconcreting process The monitoring piles' parameters are depth pressure of concrete mix concrete volume and shape of piles 34 35 Design of Bored Piles in sandy soil 35 36 Get Price

Types and Causes of Concrete Deterioration

process is called corrosion For corrosion to occur four elements must be present Minimum Concrete Cover Requirements (ACI 318) Cast-In-Place Concrete Min cover mm low cement content short curing period low strength and highly permeable or porous paste Carbonation is highly dependent on the relative humidity of the concrete Get Price

Excavations and Excavation Supports

Soldier piles or soldier beams are H-piling set in predrilled holes around the periphery of an excavation Predrilling as opposed to driving is used to provide close control of alignment and location These piles are then grouted in place with weak concrete Lagging is the timber Get Price

cfa PiLes

All rigs have an auto-concreting facility to ensure pile integrity during the concreting process whilst at the same time minimising concrete waste within the bore and at the head of the pile The data is analysed on site to produce graphical representations of pile conformity Data is then stored centrally to provide historical reference Get Price